hello@brookvent.ie01 546 1004
  • Rep. of Ireland
    • GB
    • Poland
    • Lithuania
    • Estonia
    • Latvia
    • Hungary
    • Bulgaria
  • Services/Info
    • Building Regulations Republic of Ireland
  • About
    • Who we are
    • Accreditations
    • Awards
    • Careers
  • Contact
    • Contact Us
    • Office Locations
    • International Distributors
    • Terms & Conditions
    • Delivery & Returns
    • Faulty Product
    • Privacy
    • Sitemap
Top Bar
Quick Search
€0.00
BrookventBrookvent
Brookvent
Mechanical, Heat Recovery Ventilation and Window Ventilation, Northern Ireland, UK Mainland
  • Heat Recovery
    Ventilation
    • Heat Recovery Introduction
    • aircycle 1.2 Heat Recovery Ventilation System
    • Aircycle 1.3 Heat Recovery Ventilation System
    • Aircycle 1.3 Heat Recovery Ventilation Digital Range
    • Aircycle 3.1 Heat Recovery Ventilation Digital Range
    • Aircycle 4.1 Heat Recovery Ventilation Digital Range
    • Refurbished Aircycle Heat Recovery Ventilation System
    • Aircycle ONE PRO Single Room Heat Recovery System
    • aircycle ONE Single Room Heat Recovery System
    • aircycle ONE+ Single Room Heat Recovery System
    • NOX 50
    • NOX 100
    • FAQ’s/ Information
  • Mechanical
    Ventilation
    • Introduction
    • airstream ACE
    • airplus PIV
    • Airstream Decentralised Mechanical Extract Ventilation DMEV
    • airstream 1.1 E
    • airstream 1.1 EH
    • airstream Xe
    • airstream Xe+
    • BTP EC Duct Fan
    • AP Evo Air Purifier
    • FAQ’s/ Information
  • Ducting,
    Accessories
    & Filters
    • Introduction
    • airduct FIREBRICK
    • Semi Rigid Range
    • Filters
    • Accessories
    • Replacement Parts
  • Vents
    • Surface Mounted / Throught The Frame Vents
      • SM 1000
      • SM 1000+
      • SM 1200
      • SM 1200+
      • SM 1400
      • Acoustic Vents
      • SM TIP VENT
      • SM TIP VENT EVOLUTION
    • Glazed in Vents
      • DG 1500
      • DG Standard
      • Thermal Break
      • PD
      • DG 75
      • DG 80
      • DGL 80
      • DGL SUPER
    • Over Frame Vents
      • OF STANDARD
      • OF ACO
      • OF SUPER
    • Acoustic Vents
      • SM Ultima
      • OF Aco
      • OF Super
      • SM Acoustic
      • DGL Super
      • Aquvent
    • Specialist Vents
      • Gas Vent (Always open)
      • Hunidity control
      • Ultra high weather
    • Wall Vents
      • Introduction
      • Aquwall HY+/ Aquwall SI HY+
      • Aquwall Press
  • News
    • News
    • Blogs
    • Projects
  • Louvres
    • Standard ventilation louvres
      • Flanged Wall Louvres
        • BRL20V-FL
        • BRL34V-FL
        • BRL50Z-FL
        • BRL60Z-FL
        • BRL65Z-FL
        • BRL75Z-FL
      • Glazed-in Louvres
        • BRL20V-GL
        • BRL34V-GL
        • BRL50Z-GL
        • BRL60Z-GL
      • Surface Mounted Louvres
        • BRL20V-SM
    • Ventilation louvres with increased flow area (HF)
      • Flanged Wall Louvres
        • BRL34Z-FL HF
      • Glazed-in Louvres
        • BRL34Z-GL HF
      • Surface Mounted Louvres
        • BRL34Z-SM HF
    • Ventilation Louvres with increased water resistance (EWR)
      • Flanged Wall Louvres
        • BRL34Z-FL EWR
        • BRL50Z-FL EWR
        • BRL60Z-FL EWR
        • BRL65Z-FL EWR
        • BRL75Z-FL EWR
      • Glazed-in Louvres
        • BRL34Z-GL EWR
        • BRL50Z-GL EWR
        • BRL60Z-GL EWR
      • Surface Mounted Louvres
        • BRL34Z-SM EWR
  • Thermoscreens
    • Air Curtain Products
    • Surface Mounted Air Curtains
      • C Series
      • C Series Designer
      • Compact 2
      • HP Series
      • HX Series
      • Thermoscreens HX CS Cold Store
      • IP Series
      • Jet3 overdoor heater
      • PHV
      • PHV Designer
      • PHV Vertical
      • T Series
      • EcoPower remote control and monitoring (SM)
    • Recessed
      • C Series
      • Compact 2
      • HX Series
      • PHV
      • T Series
      • T600 and T800 Thermal Air Heaters
      • EcoPower remote control and monitoring
  • Biddle
    • Climate Control Solutions
    • Comfort Air Curtains
      • SR Air Curtain
      • Invisidor City Comfort Air Curtain
      • Invisidor Style Designer Air Curtain
      • Invisidor Doorflow Comfort Air Curtain
    • Industrial Air Curtains
      • Indac2 Air Curtain
      • IsolAir2 Chilled Room Air Curtain
      • MAT Cold Store Air Curtain
    • Industrial Heaters
      • Noz2 Ceiling Mounted Industrial Cooling
      • Noz2 Ceiling Mounted Industrial Heater
      • Uniflow Air Heater
    • Heating & Ventilation
      • Innovair Fresh Air Fan Convector
      • Comfort Circle
      • Forceflow H2
      • Forceflow LST Fan Convector
      • Forceflow CB Fan Convector
    • Heat Recovery
      • Air2Air Heat Recovery Solutions
    • Fan Coils
      • Comfort Circle Cassette Units
      • Deco Fan Coil Units
      • Isotherm Fan Coil Units
      • Modulair Fan Coil Units
Menu back  
  1. Home
  2. Replacement Parts
  3. Brookvent Aircycle 1.2/1.3/1.3+ Front Panel Kit

Brookvent Aircycle 1.2/1.3/1.3+ Front Panel Kit

Product Code: AS 90-09-904

Please indicate on checkout in the “

€32.50 + VAT




Related Products

  • Heat-Exchange-Core-Front-600×482[1]

    Brookvent Aircycle 1.3+ Replacement Heat Exchanger Core

    The Aircycle 1.3 Heat Recovery Core is protected by two filters. As long as the filters are regularly changed as detailed in the previous section there should be no need to access the system’s heat recovery core. However, should regular filter changes not be adhered to it may be advisable to access the system’s heat recovery core, and where required, clear it of any debris that may have collected.

    Step By Step Process:

    Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected. Never run the system with the MVHR heat exchange core removed.
    Step 2. Remove both filters.
    Step 3. Remove the front door panel via its 8 screws.
    Step 4. Remove the foam panels and then the heat exchanger from the unit by pulling the plastic strip running across the front of the heat exchanger.
    Step 5. Carefully remove any dust from the heat exchanger with a household vacuum cleaner. Do not attempt the clean the heat exchanger with any fluids.
    Step 6. Carefully reinsert the replacement heat exchange core into the unit and the foam panels.
    Step 7. Reinsert both filters (change if necessary) and replace the front door ensuring all four screws are securely fastened. Also ensure the filter tabs on the front of the unit are securely fitted.
    Step 8. Power the unit on at the isolator and ensure any supply circuits are reconnected.

    Product Code: AS 90-09-905

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    https://brookvent.co.uk/product/aircycle-1-3-house-ventilation-system/

  • Heat-Exchange-Core-Front-600×482[1]

    Brookvent Aircycle 1.3 Replacement Heat Exchanger Core

    The Aircycle 1.3 Heat Recovery Core is protected by two filters. As long as the filters are regularly changed as detailed in the previous section there should be no need to access the system’s heat recovery core. However, should regular filter changes not be adhered to it may be advisable to access the system’s heat recovery core, and where required, clear it of any debris that may have collected.

    Step By Step Process:

    Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected. Never run the system with the MVHR heat exchange core removed.
    Step 2. Remove both filters.
    Step 3. Remove the front door panel via its 8 screws.
    Step 4. Remove the foam panels and then the heat exchanger from the unit by pulling the plastic strip running across the front of the heat exchanger.
    Step 5. Carefully remove any dust from the heat exchanger with a household vacuum cleaner. Do not attempt the clean the heat exchanger with any fluids.
    Step 6. Carefully reinsert the replacement heat exchange core into the unit and the foam panels.
    Step 7. Reinsert both filters (change if necessary) and replace the front door ensuring all four screws are securely fastened. Also ensure the filter tabs on the front of the unit are securely fitted.
    Step 8. Power the unit on at the isolator and ensure any supply circuits are reconnected.

    Product Code: AS 90-09-906

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    https://brookvent.co.uk/product/aircycle-1-3-house-ventilation-system/

  • 1.2-PCB-Front-600×450[1]

    Brookvent Aircycle 1.2/1.3/1.3+ Dial operated PCB kit.

    In the unlikely event of an electronic PCB failure, the Aircycle 1.3’s PCB module can be disconnected and replaced.

     

    Step 1. PCB replacement should only be completed by a qualified Electrician.
    Step 2. Ensure all circuits are isolated before working on the unit.
    Step 3. When handling the PCB’s ensure the devices are grounded to prevent electrostatic discharge from damaging the components.
    Step 4. To locate the PCB in the correct position; line the feet A & B on the PCB along the edge of the enclosure as shown.
    Step 5. Also line the edge of foot A shown against the yellow stand-off in the enclosure.
    Step 6. This will ensure that the spindles line up with the holes in the enclosure lid.
    Step 7. For inverted units (white label) line foot A up with the opposite edge and with the yellow stand off on the bottom right (i.e. the same position as the one being replaced).
    Step 8. Wire the PCB as shown on the other page (note there are two sensors wired in the interface terminal, the unit may not work if only one is wired).
    Step 9. When the unit is wired and fixed in place; insert the spindles in the potentiometers.
    Step 10. To do this ensure all the potentiometers are turned fully anti-clockwise.
    Step 11. Insert the spindles with the slot in the direction shown.
    Step 12. Replace the cover and screw it in place.
    Step 13. Re-connect the power.
    Step 14. Recommission the system.

     

    If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk

    https://brookvent.co.uk/product/aircycle-1-3-house-ventilation-system/

     

     

Ducting, Accessories & Filters
  • Introduction
  • airduct FIREBRICK
  • Semi-Rigid Ducting
  • Filters
  • Replacement Parts
Latest news
  • easter
    Happy Easter from Brookvent
    April 2, 2026
  • black friday
    Black Friday 2025 Deals – Biggest Sale of the Year!
    November 6, 2025
  • Merry Christmas and Happy New Year from Brookvent
    December 20, 2024
  • Black Friday of 2024 is now on. Get some of our best deals ever!
    November 7, 2024
Latest blogs
  • brookvent louvre
    Enhance Airflow, Efficiency, and Aesthetics with Louvres
    October 31, 2025
  • How to Choose the Perfect Ventilation System for Your Home
    December 5, 2024
  • Combatting Hay Fever: Solutions for a Pollen-Free Home
    Combatting Hay Fever with Air Filters: Solutions for a Pollen-Free Home
    July 22, 2024
  • New vs. Older Homes: What You Need to Know About Ventilation
    New vs. Older Homes: What You Need to Know About Ventilation
    July 19, 2024
Got a question? Get in touch

    Name*

    Email*

    Location*

    Message

    How did you find Brookvent?

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    • Amazon integration
    • About
    • News
    • Blog
    • Delivery & Returns
    • Terms & Conditions
    • Faulty Product
    • Privacy
    • Sitemap
    • Amazon
    Brook House, Dunmurry Industrial Estate, Dunmurry, Belfast, Co. Antrim, BT17 9HU
    Tel: +44 (0)28 9061 6505 / Fax: +44 (0)28 9061 6518 / Email: hello@brookvent.co.uk
    Registered in Northern Ireland with Company No: NI 019735

    © 2026 Website by WDMA