Brookvent Aircycle 3.1/4.1 Front Panel Kit
Product Code: AS 90-09-810
Please indicate in the order notes which version you need (e.g. 3.1 or 4.1)
A Brookvent Aircycle 1.2,1.3 and 1.3+Replacement Wall Bracket Kit. Product Code: AS 90-09-909
The unit should be attached to the wall using the wall bracket provided, please ensure the mounting surface can safely bear the load of the unit using suitable screw fixings.
Step by Step Instructions for Wall Mount:
Remove the existing bracket which will be secured to the back of the unit and replace with new one.
The second bracket should be secured to the mounting surface (wall) Please ensure the brackets are level.
The unit can then be set onto the mounting surface with the lip of each bracket
Ensure the system is level when fully mounted.
Ensure the unit is fully attached and secure.
If you have any questions regarding this procedure, please get in contact with the office on 02890616505 or hello@brookvent.co.uk
https://brookvent.ie/product/aircycle-1-3-house-ventilation-system/
€21.00 + VAT
Brookvent Aircycle 3.1/4.1 Front Panel Kit
Product Code: AS 90-09-810
Please indicate in the order notes which version you need (e.g. 3.1 or 4.1)
Brookvent Aircycle 1.3 Replacement Heat Exchanger Core
The Aircycle 1.3 Heat Recovery Core is protected by two filters. As long as the filters are regularly changed as detailed in the previous section there should be no need to access the system’s heat recovery core. However, should regular filter changes not be adhered to it may be advisable to access the system’s heat recovery core, and where required, clear it of any debris that may have collected.
Step By Step Process:
Step 1. Isolate the unit from the mains and ensure all supply circuits are disconnected. Never run the system with the MVHR heat exchange core removed.
Step 2. Remove both filters.
Step 3. Remove the front door panel via its 8 screws.
Step 4. Remove the foam panels and then the heat exchanger from the unit by pulling the plastic strip running across the front of the heat exchanger.
Step 5. Carefully remove any dust from the heat exchanger with a household vacuum cleaner. Do not attempt the clean the heat exchanger with any fluids.
Step 6. Carefully reinsert the replacement heat exchange core into the unit and the foam panels.
Step 7. Reinsert both filters (change if necessary) and replace the front door ensuring all four screws are securely fastened. Also ensure the filter tabs on the front of the unit are securely fitted.
Step 8. Power the unit on at the isolator and ensure any supply circuits are reconnected.